EVM-7 Advanced Particulate and Air Quality Monitor with PID (ppb) Sensor and CO2 Sensor, two 37mm Gravimetric Filter Cassettes

TSI Quest

RN-EVM-7-PPB

Call to Order
Rental Options: Daily, Weekly, Monthly
not_listed_location

Questions about this product?

Speak to an expert

call mail

The Quest EVM Series monitors for particulates and air quality in one compact instrument providing a lower cost of ownership by combining three instruments into one.

Features:

  • Kit includes base model with Particulate sensor, PID (ppm) sensor, CO2 sensor, (2) 37 mm gravimetric filter cassettes and standard accessories.
  • Simultaneous measurement of particulate and CO2, VOC, Temperature and Relative Humidity concentrations.
  • Dial-in rotary impactor.
  • 90 degree light scattering photometer.
  • Built-in sampling pump for gravimetric analysis.

EVM-3 - Specializes in real-time direct reading of particulate concentrations. This tri-sensor instrument utilizes the
built-in sampling pump and dial-in impactors for real-time mass concentration readings.
EVM-3 measures:
• Particulates (mass concentration)
• Temperature
• Relative Humidity

EVM-4 - Multi-sensor instrument designed for indoor air quality investigations. Simultaneously track, log and monitor multiple indoor air quality parameters, including room air exchange rates and dew point.
EVM-4 measures:
• Gas (choose from nine sensors)
• Relative Humidity
• Carbon Dioxide
• Temperatur

The EVM-7 is a durable yet lightweight instrument designed for real-world use. It can be tripod mounted or hand-held, making it well suited for a variety of area monitoring applications, including:
• Industrial hygiene area surveys
• LEED building clearance screening
• Construction / mining site monitoring
• Engineering studies
• Industrial fence line monitoring
• IAQ walk-through and stationary studies
• Air quality assessment
• VOC screening and monitoring

Simultaneous Measurement of Particulate and Gas Concentrations - Reduces the need for multiple instruments and lowers the cost of ownership.
Dial-in Rotary Impactor - Twist and click selection of particulate settings: PM2.5, PM4, PM10 or TSP.
90° Light Scattering Photometer - Provides real-time measurement of particulates.
Built-in Sampling Pump for Gravimetric Analysis - Allows user to insert a 25 or 37 mm cassette to capture particulate samples for laboratory testing.

Models

EVM-7/CO EVM-7 Advanced Particulate and Air Quality Monitor with CO Sensor Includes:

Base model with PID (ppm) Sensor, CO2 Sensor, CO Sensor, two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-7 EVM-7 Advanced Particulate and Air Quality Monitor Includes:

Base model with PID (ppm) Sensor, CO2 Sensor, one Dummy Sensor (used to seal socket when no sensor is present), two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-7/CO-PPB EVM-7 Advanced Particulate and Air Quality Monitor with CO Sensor & PPB Includes:

Base model with PID (ppb) Sensor, CO2 Sensor, CO Sensor, two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-104 PID (ppb) Electrode (Grid) Pellet, 74-720 Dust Zero Calibration Filter Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-7-PPB EVM-7 Advanced Particulate and Air Quality Monitor with PPB Includes:

Base model with PID (ppb) Sensor, CO2 Sensor, one Dummy Sensor (used to seal socket when no sensor is present), two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-104 PID (ppb) Electrode (Grid) Pellet, 74-720 Dust Zero Calibration Filter Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-4/CO EVM-4 Indoor Air Quality Monitor with CO Sensor Includes:

Base model with CO2 Sensor, CO Sensor, one Dummy Sensor (used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-4 EVM-4 Indoor Air Quality Monitor Includes:

Base model with CO2 Sensor, two Dummy Sensors (used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 74-726 Toxic Calibration Adapter and 74-718 Storage Case.

EVM-3 EVM-3 Real-Time Direct Reading Particulate Monitor Includes:

Base model with two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), three Dummy Sensors (used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, and 74-718 Storage Case.

Specifications:

  • Air Velocity: Yes
  • Battery Life: 8 Hours
  • Battery Type: Rechargeable
  • Data Logging: Yes
  • Kits & Systems: Kits
  • Kit Type: Air Quality Monitor Kit
  • Measurement Parameters: Avg, Level, Max, Min, STEL, TWA
  • Net Weight: 18 oz
  • Product Series: EVM
  • Product Type: Kits, Particulate and Air Quality Monitor
  • Sensor Type: Included Sensors: Relative Humidity, Temperature, CO2, CO, Particulates, PID ppm Available
  • Sensors: O2, H2S, NO, NO2, HCN, EtO, CL2, S02, PID ppb, Air Velocity
  • Standards/Approvals: CE, CE, RoHS
  • US Govt Contract Number: GS-07F-010CA

Applications:

  • Work Site Monitoring
  • Air Quality Assessment
  • Military Site Evaluation
  • Construction / Mining Site Monitoring
  • Regulatory Compliance
  • Time-History Assessment
  • Industrial Fence Line Monitoring
  • Industrial Hygiene SurveysThe EVM Series monitors for particulates and air quality in one compact
  • Instrument providing a lower cost of ownership by combining three instruments into one.
More Information
PN RN-EVM-7-PPB
Manufacturer TSI Quest
Unit of Measure ea
Copyright © 2021 Concept Controls Inc.